24Fabrication and alteration are detectable in principle by asking the named laboratory whether it issued the report. Whether that is possible depends on the laboratory's practice; some issue reports with a verifiable reference and some do not. A report that cannot be checked with its issuer is not thereby forged — most are not — but it is unconfirmable.{{r|iso17025}}24Fabrication and alteration are detectable in principle by asking the named laboratory whether it issued the report. Whether that is possible depends on the laboratory's practice; some issue reports with a verifiable reference and some do not. A report that cannot be checked with its issuer is not thereby forged — most are not — but it is unconfirmable.{{r|iso17025}}
2525
+26== Internal signals ==
+27Some fabrications are visibly defective, and the defects are usually arithmetic or procedural rather than typographic.
+28
+29* Dates out of order: testing before manufacture, release before testing, retest before release.
+30* A stated method incapable of producing a reported determination — a purity figure attributed to a method that does not separate, or a water figure attributed to a method that does not measure water.
+31* Determinations reported to more significant figures than the method supports.
+32* Related-substance figures that do not sum consistently with the reported main-peak area.
+33* A chromatogram whose visible integration does not correspond to the stated figure.
+34
26== References ==35== References ==
27{{reflist}}36{{reflist}}