| Revision 4 — 16:00, 7 Aug 2024 LipidLedgerLou (talk) add the cost basis, since it shapes who submits 2,054 bytes ±0 | Revision 5 — 00:37, 22 Aug 2024 BlindSampleBrid (talk) split §What a report shows from §What it does not 2,527 bytes +473 | ||
|---|---|---|---|
| 10 | Its distinguishing documented practice is the release of the underlying chromatogram alongside the numeric result. A released chromatogram allows a reader to see peak shape, baseline, integration boundaries and the presence of minor peaks, none of which is recoverable from a single [[Area percent purity|area percent]] figure.{{r|usp1503}} | 10 | Its distinguishing documented practice is the release of the underlying chromatogram alongside the numeric result. A released chromatogram allows a reader to see peak shape, baseline, integration boundaries and the presence of minor peaks, none of which is recoverable from a single [[Area percent purity|area percent]] figure.{{r|usp1503}} |
| 11 | 11 | ||
| + | 12 | Reports are issued to the submitter rather than to the supplier of the material. This is the structural feature that makes them [[Third-party testing|third-party]] rather than supplier-commissioned, and it is independent of the analytical quality of the work, which is governed by ordinary laboratory competence requirements.{{r|iso17025}} | |
| + | 13 | ||
| 12 | == What the reports contain == | 14 | == What the reports contain == |
| 13 | Reports submitted to this wiki by contributors have consistently included a chromatogram, an area percent purity figure with the integration visible, and — where requested — a mass determination confirming the observed mass against the calculated one.{{r|reports}} | 15 | Reports submitted to this wiki by contributors have consistently included a chromatogram, an area percent purity figure with the integration visible, and — where requested — a mass determination confirming the observed mass against the calculated one.{{r|reports}} |
| ⋮ | ⋮ | ||
| 19 | <ref name="reports">PeptidePedia Wiki community test-report tally, 2024–2026 (self-reported; see [[Project:Sourcing_guidelines]]).</ref> | 21 | <ref name="reports">PeptidePedia Wiki community test-report tally, 2024–2026 (self-reported; see [[Project:Sourcing_guidelines]]).</ref> |
| 20 | <ref name="usp1503">United States Pharmacopeia, General Chapter <1503>, ''Quality Attributes of Synthetic Peptide Drug Substances''.</ref> | 22 | <ref name="usp1503">United States Pharmacopeia, General Chapter <1503>, ''Quality Attributes of Synthetic Peptide Drug Substances''.</ref> |
| + | 23 | <ref name="iso17025">ISO/IEC 17025:2017, ''General requirements for the competence of testing and calibration laboratories''.</ref> | |
| 21 | 24 | ||