| 142 | USP <1660> provides the compendial approach to evaluating inner-surface durability, combining accelerated attack under defined conditions with surface analysis and with examination for lamellae. Its purpose is prospective screening during development rather than release testing, because the phenomenon develops over storage and a release test cannot detect it.{{r|usp1660}} | 142 | USP <1660> provides the compendial approach to evaluating inner-surface durability, combining accelerated attack under defined conditions with surface analysis and with examination for lamellae. Its purpose is prospective screening during development rather than release testing, because the phenomenon develops over storage and a release test cannot detect it.{{r|usp1660}} |
| 143 | 143 | ||
| + | 144 | Other glass defects are more mundane and more common: chips at the sealing land, which prevent sealing; stones and cords, which are inclusions and inhomogeneities weakening the wall; and scratches from handling, which initiate breakage. Inspection for these is a fill-finish activity and is treated at [[Vial filling and stoppering]]. | |