40'''The container differs.''' Adsorption to glass, extractables from a stopper, and headspace oxygen all affect degradation rate. A figure obtained in a Type I glass vial with a coated stopper does not transfer to an uncoated one.40'''The container differs.''' Adsorption to glass, extractables from a stopper, and headspace oxygen all affect degradation rate. A figure obtained in a Type I glass vial with a coated stopper does not transfer to an uncoated one.
4141
+42'''The temperature history differs.''' A nominal 2–8 °C figure assumes 2–8 °C throughout. Real distribution includes [[Temperature excursion|excursions]], and the mean kinetic temperature of a shipment can exceed its nominal condition substantially.{{r|ich}}
+43
42== References ==44== References ==