PeptidePedia The community reference

Insulin syringe unit conversion: difference between revisions

Diff·revision 21 → 22·14:10, 14 Feb 2025

Difference between revision 21 and revision 22 of Insulin syringe unit conversion. 3 lines changed; the page grew by 335 bytes.

Revision 21 — 15:31, 4 Feb 2025
NotabilityNoa (talk)
label community tally as self-reported
3,205 bytes ±0
Revision 22 — 14:10, 14 Feb 2025
MergeMorwenna (talk)
expand §Sources of error
3,540 bytes +335
1{{Infobox tool1{{Infobox tool
2| name = Insulin syringe unit conversion2| name = Insulin syringe unit conversion
+3| subtitle = Interactive reference tool
3| image = syringe.svg4| image = syringe.svg
4| caption = A "unit" is a volume, defined by the syringe, not a quantity of drug.5| caption = A "unit" is a volume, defined by the syringe, not a quantity of drug.
3435
35The U-100 and U-50 columns are identical because both use a 0.01 mL graduation; they differ in barrel capacity and therefore in the physical spacing of the marks, which is the point of the U-50 syringe. The U-40 column is the hazardous one: an identical reading corresponds to two and a half times the volume.36The U-100 and U-50 columns are identical because both use a 0.01 mL graduation; they differ in barrel capacity and therefore in the physical spacing of the marks, which is the point of the U-50 syringe. The U-40 column is the hazardous one: an identical reading corresponds to two and a half times the volume.
+37
+38A reader who transfers a "20 unit" figure from a U-100 context to a U-40 syringe delivers 0.5 mL instead of 0.2 mL. Reports of this error in the veterinary and human literature are consistent enough that colour-coded caps — orange for U-100, red for U-40 — are conventional.{{r|fdavet}}
3639
37== References ==40== References ==