PeptidePedia The community reference

Haemoglobin A1c (revision 8)

Old revision·19:41, 19 Nov 2024·DrTitration

This is an old revision of this page, as it stood at 19:41, 19 Nov 2024, saved by DrTitration with the summary de-orphan. It may differ substantially from the current revision, and any error it contains may since have been corrected.
Haemoglobin A1cLaboratory medicine
AbbreviationHbA1c
ReflectsAverage glucose over ~8–12 weeks
Unitsmmol/mol (IFCC); % (DCCT/NGSP)
Confounded byAnything altering red-cell lifespan
Topic infobox · conventions

Haemoglobin A1c is the fraction of haemoglobin that has been non-enzymatically glycated. Because glycation is irreversible and proceeds at a rate proportional to glucose concentration, the fraction integrates glucose exposure over the lifespan of the circulating red cells — roughly the preceding eight to twelve weeks, weighted towards the more recent.[1]

It is reported in two unit systems: mmol/mol under the IFCC reference method, and percentage under the older DCCT-aligned convention. Both appear in the literature and conversion between them is defined.[2]

Its principal limitation follows from its mechanism: anything that alters red-cell lifespan alters the result independently of glucose. Haemolysis and blood loss lower it; iron deficiency and reduced turnover raise it.[1]

What it measures

[edit]

Glycation is a slow non-enzymatic reaction between glucose and the N-terminal valine of the haemoglobin β-chain. Its extent depends on both glucose concentration and exposure time, and because red cells are replaced continuously the population of cells sampled at any moment carries a weighted history.[2]

The weighting is not uniform: roughly half the value reflects the preceding month, and the remainder the two months before. A change made three weeks ago is therefore only partly expressed.[1]

Estimated average glucose can be derived from HbA1c by a published regression, and the derivation carries substantial individual variation — two people with identical HbA1c can have appreciably different mean glucose.[2] The measure is a laboratory determination with its own method dependence, as any determination is.[3]

References

  1. ^ a b c American Diabetes Association. "Standards of Care in Diabetes." Diabetes Care 47(Suppl 1) (2024).
  2. ^ a b c Nathan DM, Kuenen J, Borg R, et al. "Translating the A1C assay into estimated average glucose values." Diabetes Care 31(8):1473–1478 (2008). PMID 18540046.
  3. ^ United States Pharmacopeia, General Chapter <1503>, Quality Attributes of Synthetic Peptide Drug Substances.